Column End Drilling + Screw Leg

You can connect a column end to a log wall using an end drilling and screw leg joint. The joint adds machining to the column. The joint is also displayed in the log work drawing. If you remove or add logs above or below the column, the joint will follow.

  1. Activate the model window.
  2. Select Beams, Columns > Connection Details. The browser opens.
  3. Select the Log Walls folder in the browser.
  4. Select the 0004 Column end drilling + screw leg joint.
  5. Select a log wall.
  6. Select the ends of the columns to be connected.
  7. Select Confirm. The Column Screw Leg Joint dialog box will open.
  8. Define the joint parameters in the dialog box.

    Confirm by clicking OK.

  9. If you have created a joint between the column and the wall earlier, delete the old joint by selecting Delete in the message box.
Note

Adding a Log Column
Column End Tenon Joint
Vertex Browser