Redefining a Zone

If you add or remove structures within an energy zone, redefine the zone. Use the document browser function.

  1. Activate the model window.
  2. Open the Energy calculation branch in the document browser.
  3. Move the cursor over the Warm [number] or Half warm [number] header.
  4. Right-click to open the context-sensitive menu.
  5. Select Edit. The program hides all the other objects, besides walls, from the model, and highlights the walls included in the zone in color.
  6. Click to add or remove walls. Only select walls included in the energy zone (heated or semi-heated) in question.
  7. Select Confirm. The program hides all the other objects, besides horizontal structures and walls, from the model.
  8. Select the horizontal structures.

    The selected structures are opened in the Energy Zone Definitions dialog box.

  9. Edit the space volumes that are used in the energy calculation in the dialog box.

    Energy Zone Definitions Dialog Box

  10. Confirm by clicking OK.

    The program generates a space volume based on the selected walls and horizontal structures and the offsets defined for the structures.

    The program collects the building component data in a database and opens them for viewing in the Thermal Insulation Components database view.

    The Thermal Insulation Components Database View

  11. Confirm by clicking OK.

    The program will update the energy report (energy.xml) in the project folder. You can open the report in the project document browser.

Note

Determining the North Direction
Defining a Zone
Updating a Zone
Showing and Hiding a Zone
Restoring the Geometry of Building Components to a Model
Energy Zones
Energy Calculation