Part Protection
When you add parts to a structure, the parts are added to all
the layers of the structure for which a framing tool has been
defined and the parts of which are not protected.
You can set part protection for a layer as follows:
- Activate the model window.
- Select the structure – a wall panel, for example.
- Select the structural layer – a wall panel layer, for
example.
- Right-click to open the context-sensitive menu.
- Select Set Part Protection.
When you add parts to a structure using the function
Generate Parts, you will see a message
regarding any protected layers in the structure. Select one of the
following:
- Continue - Parts are not added to the protected layer.
Parts previously added to the layer remain the same
- Remove Part Protection - The layer protection is removed
and the parts are added.
- Cancel - Cancel the function.
You can remove a layer's protection by selecting Remove Part
Protection in the context-sensitive menu.
Note
- An exception to this is the sheathing layer of a wall panel,
which is affected by the parameters of the frame's framing
tool.
- The protection of layer parts does not prevent the removal of
parts using the function Remove
Parts.
Add
Parts