Piping Design

Set Connection Tolerance for Parts

What the angle tolerance does in practice is that, when routing a pipe or duct line between two straight lines, for example, an elbow will not be added if the angle is less than the angle tolerance value.

Correspondingly, when ending a line, for example, a connection to another section can be added without an elbow if the angle is less than the angle tolerance value.

The angle tolerance also affects the editing of the slope. If the angle of a bend at the set slope is less than the minimum angle of the curve or exceeds its maximum angle, editing can be conducted within the angle tolerance.

The default value for an angle tolerance is 1.0.

You can set the connection tolerance when adding a pipe or duct line, or pipe or duct component, or when editing the properties of a pipe line.

  1. Select from the toolbar.
  2. Define the information in the dialog box fields.
  3. Accept the data.

Pipe or Duct Line Properties
Pipe or Duct Component Properties

Converted from CHM to HTML with chm2web Pro 2.85 (unicode)