Add distance constraints to the eaves of the crossing roof

The distance constraint adding function is still in use.

  1. Continue by adding a distance constraint between the outer surface line of the wall in the reference drawing and the roof line on the side eaves (A).

    Define the following data for the constraint:

    • Enter the distance Value: 500.
    • Tick the Controls eave height checkbox.

    Confirm by clicking OK.

  2. Add a similar distance constraint to the side eaves (B).
  3. Add a distance constraint with the value 500 to the gable eaves (C).
  4. Quit by pressing the Esc key.